Please use this identifier to cite or link to this item: http://repositorio.ufpso.edu.co/jspui/handle/123456789/3456
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGómez Camperos1, July Andrea
dc.contributor.authorRegino Ubarnes, Fernando
dc.contributor.authorEspinel Blanco, Edwin
dc.coverage.spatialOcaña Norte de Santander, Colombia.en_US
dc.date.accessioned2021-09-28T00:08:46Z
dc.date.available2021-09-28T00:08:46Z
dc.date.issued2018
dc.identifier.citationGomez Camperos, J. A., Ubarnes, F. R., & Blanco, E. E. (2018). Experimental study for detection of leaks in horizontal pipelines. Contemporary Engineering Sciences, 11(101), 5017–5025. https://doi.org/10.12988/ces.2018.810551en_US
dc.identifier.issn1314-7641en_US
dc.identifier.urihttp://repositorio.ufpso.edu.co/jspui/handle/123456789/3456
dc.description.abstractThis document presents an experimental study of the flow behavior and pressure of liquids in horizontal pipes, in the presence and absence of leaks in a transitory state. For the development of the investigation, an experimental assembly was constructed in the Fluid Mechanics laboratory of the Francisco de Paula Santander University Ocaña (UFPSO). To simulate the leakage in water conduction in pipes, two pressure sensors and two flow sensors were installed at the beginning and at the end of the pipe to measure the pressure and flow in the system, a data acquisition equipment and a Virtual Instrument that was developed in the labview Software that allows detecting a leak in real time was used, ensuring its presence and correction immediately.en_US
dc.description.sponsorshipUniversidad Francisco de Paula Santander Ocaña, Colombia.en_US
dc.description.tableofcontentsspa
dc.format.mimetypespa
dc.language.isoengen_US
dc.publisherAndrea Colantonien_US
dc.relationhttp://www.m-hikari.com/ces/index.htmlen_US
dc.relation.ispartofseriesINGAP;ART04
dc.relation.uri
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.subjectPID Tunind, modelado, tuberías hidráulicas, detección de fallas, tubería,monitoreo, sistemas de diagnóstico.en_US
dc.titleExperimental Study for Detection of Leaks in Horizontal Pipelinesen_US
dc.typeArtículoen_US
dc.title.translatedEstudio Experimental para Detección de Fugas en Tuberías Horizontalesen_US
dc.description.abstractenglishThis document presents an experimental study of the flow behavior and pressure of liquids in horizontal pipes, in the presence and absence of leaks in a transitory state. For the development of the investigation, an experimental assembly was constructed in the Fluid Mechanics laboratory of the Francisco de Paula Santander University Ocaña (UFPSO). To simulate the leakage in water conduction in pipes, two pressure sensors and two flow sensors were installed at the beginning and at the end of the pipe to measure the pressure and flow in the system, a data acquisition equipment and a Virtual Instrument that was developed in the labview Software that allows detecting a leak in real time was used, ensuring its presence and correction immediately.en_US
dc.subject.proposaleng
dc.subject.keywordsPID Tunind, modeling, Hydraulic pipes, fault detection, pipeline monitoring, diagnostic systems.en_US
dc.subject.lembspa
dc.identifier.instnameinstname:Universidad Francisco de Paula Santander Ocañaspa
dc.identifier.reponamereponame:Repositorio Institucional UFPSOspa
dc.identifier.repourlrepourl:https://repositorio.ufpso.edu.cospa
dc.publisher.facultyFacultad ingenieríasen_US
dc.publisher.grantorUniversidad Francisco de Paula Santander Ocañaspa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.accessrightshttp://purl.org/coar/access_right/c_abf2
dc.rights.creativecommonsAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rights.localspa
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.driverinfo:eu-repo/semantics/article
dc.type.localArtículoen_US
dc.type.redcolArtículo de investigación http://purl.org/redcol/resource_type/ART Artículo de divulgación http://purl.org/redcol/resource_type/ARTDIV*
dc.relation.referencesL. Billman, R. Isermann, Leak detection methods for pipelines, Automatica, 23 (1987), no. 3, 381- 385. https://doi.org/10.1016/0005-1098(87)90011-2en_US
dc.relation.referencesJ.S. Chen, R. Patton, Robust Model-Based Fault Diagnosis for Dynamic Systems, Springer, Kluwer Academic Publishers, Boston 1999. https://doi.org/10.1007/978-1-4615-5149-2en_US
dc.relation.referencesD. Marrugo, Desarrollo de un Instrumento Virtual para la Generación de perfiles de Temperatura en Hornos, Revista INGENIO UFPSO, 8 (2015), 47- 58. Experimental study for detection of leaks in horizontal pipelines 5025en_US
dc.relation.referencesQuintero Pedro, Desarrollo De Un Sistema Para Detección De Fugas Para Tuberías Horizontales En Tiempo Real Por Medio De Gradientes Depresión, PhD Tesis, Instituto Tecnológico y de Estudios Superiores de Monterrey, 2017.en_US
dc.relation.referencesM. Turkowski, A. Bratek, M. Słowikowski, Methods and Systems of leak detection in long range pipelines, Journal of Automation Mobile Robotics and Intelligent Systems, 1 (2008), 32-52.en_US
dc.relation.referencesX. Yang, L. Jia, S. Wang, J. Wang, Based on pressure gradient model to determine leakage point in heating pipe network, Journal of Computer Modelling and New Technologies, 18 (2014), no. 5, 253-256.en_US
dc.relation.referencesD. A. Contreras Navarro, Desarrollo de un Sistema para la Detección Automática de Fugas en un Banco de Pruebas de Tuberías en la Universidad Francisco de Paula Santander Ocaña, Universidad Francisco de Paula Santander Ocaña, 2018.en_US
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.identifier.DOI10.12988/ces.2018.810551en_US
Appears in Collections:Artículos

Files in This Item:
There are no files associated with this item.


This item is licensed under a Creative Commons License Creative Commons